Aerosys is discontinued

Aerosys Replacement Units

Every discontinued model, matched to what actually fits your wall opening

Aerosys has permanently closed. If a unit just failed and you are holding a nameplate with a TTWC, TTWH, THHP, or THDC number on it, find it in the tables below. We match replacements by wall opening, because that is the constraint that actually decides what you can install. 45 discontinued models are cross-referenced here.

On refrigerant: no R-410A through-the-wall replacement is available from any manufacturer. Production ended January 1, 2025 and the install-through window closed at the end of 2025. Every replacement below is R-454B or R-32. Your existing system can still be serviced.

P Series

36" W x 19" HCustom built for this opening

The opening no manufacturer serves

The 36" x 19" P Series opening is the NYC building standard, and no manufacturer builds a unit for it today. We have ours custom fabricated to fit the existing sleeve, charged with R-454B. Built to order, 14 to 21 day lead time.

Aerosys model (discontinued)TonsReplacementRefrigerant
TTWC-R18P211.536"W x 19"H 1.5-Ton Thru-Wall CondenserR-454B
TTWC-R18P21LX1.5 LX36"W x 19"H 1.5-Ton Thru-Wall CondenserR-454B
TTWC-R24P212.036"W x 19"H 2.0-Ton Thru-Wall CondenserR-454B
TTWC-R24P21LX2.0 LX36"W x 19"H 2.0-Ton Thru-Wall CondenserR-454B
TTWC-R30P212.536"W x 19"H 2.5-Ton Thru-Wall CondenserR-454B
TTWC-R30P21LX2.5 LX36"W x 19"H 2.5-Ton Thru-Wall CondenserR-454B

T Series

24" W x 32" HWe source and install

NCP 3000 Series

The NCP 3000 Series cabinet is 24-1/8" W x 32" H, which drops into the T Series opening. Available in R-454B (NCP5 prefix) or R-32 (NCP3 prefix). We source and install these.

Aerosys model (discontinued)TonsReplacementRefrigerant
TTWC-R18T211.5NCP5183000AR-454B
TTWC-R18T21LX1.5 LXNCP5183000AR-454B
TTWC-R24T212.0NCP5243000AR-454B
TTWC-R24T21LX2.0 LXNCP5243000AR-454B
TTWC-R30T212.5NCP5303000AR-454B
TTWC-R30T21LX2.5 LXNCP5303000AR-454B

S Series

26" W x 28-5/8" HWe source and install

NCP 1000 Series

The NCP 1000 Series cabinet is 26-1/4" W x 28-5/8" H, a direct match for the S Series opening. Available in R-454B or R-32. We source and install these.

Aerosys model (discontinued)TonsReplacementRefrigerant
TTWC-R18S211.5NCP5181000AR-454B
TTWC-R18S21LX1.5 LXNCP5181000AR-454B
TTWC-R24S212.0NCP5241000AR-454B
TTWC-R24S21LX2.0 LXNCP5241000AR-454B
TTWC-R30S212.5NCP5301000AR-454B
TTWC-R30S21LX2.5 LXNCP5301000AR-454B

R Series

30" W x 23" HWe source and install

NCP 4000 Series

The NCP 4000 Series covers the R Series opening. Available in R-454B or R-32. We source and install these.

Aerosys model (discontinued)TonsReplacementRefrigerant
TTWC-R18R211.5NCP5184000AR-454B
TTWC-R18R21LX1.5 LXNCP5184000AR-454B
TTWC-R24R212.0NCP5244000AR-454B
TTWC-R24R21LX2.0 LXNCP5244000AR-454B
TTWC-R30R212.5NCP5304000AR-454B
TTWC-R30R21LX2.5 LXNCP5304000AR-454B

H Series

27" W x 44" HWe source and install

FirstCo WHSC Series

The tall H Series opening is served by the FirstCo WHSC cabinet in R-454B. Less common in NYC than the P and T openings, but we can source it.

Aerosys model (discontinued)TonsReplacementRefrigerant
TTWC-R18H211.5FirstCo 18WHSCR-454B
TTWC-R24H212.0FirstCo 24WHSCR-454B
TTWC-R30H212.5FirstCo 30WHSCR-454B

Heat Pumps

TTWH & THHP modelsWe source and install

NCP NHP Series

Aerosys heat pumps map to the NCP NHP Series, which heats and cools from one unit on 208-230V. Note the NHP 5000 Series uses a larger cabinet than the S Series opening, so an S Series swap may need the opening modified. Send us the model and we will tell you before you commit.

Aerosys model (discontinued)TonsOpeningReplacementRefrigerant
TTWH-R18T211.524" x 32" (T)NHP5183000AR-454B
TTWH-R24T212.024" x 32" (T)NHP5245000AR-454B
TTWH-R30T212.524" x 32" (T)NHP5305000AR-454B
THHP-30TGB2.524" x 32" (T)NHP5305000AR-454B
TTWH-R24S212.026" x 28-5/8" (S)NHP5245000Acheck openingR-454B
TTWH-R30S212.526" x 28-5/8" (S)NHP5305000Acheck openingR-454B

M Series

42" W x 23" HNo single-unit replacement exists

No single-unit replacement exists

Nobody builds a 3, 4, or 5 ton through-the-wall condenser as one unit anymore. The honest answer is two smaller units, which usually means a second sleeve and a second circuit. That is a design conversation, not a part number. Call us and we will lay out the options for your building.

Aerosys model (discontinued)TonsReplacementRefrigerant
TTWC-R36M213.0Two 1.5-ton unitsR-454B
TTWC-R36M21LX3.0 LXTwo 1.5-ton unitsR-454B
TTWC-R48M214.0Two 2.0-ton unitsR-454B
TTWC-R48M21LX4.0 LXTwo 2.0-ton unitsR-454B
THDC-60MG215.0Two 2.5-ton unitsR-454B
THDC-60MG21LX5.0 LXTwo 2.5-ton unitsR-454B

Chilled Water Fan Coils

DCW modelsQuoted per job

DCW replacements

Aerosys DCW chilled water fan coils have direct replacements available in galvanized or painted cabinets. These are matched on cabinet size and coil rows rather than refrigerant, so send us the model number and the loop details and we will spec it.

Aerosys model (discontinued)TonsReplacementRefrigerant
DCW-20-115V1.5Contact us to specChilled water
DCW-26-115V2.0Contact us to specChilled water
DCW-32-115V2.5Contact us to specChilled water

AboveAir VCU-C

36" W x 19" HCustom built for this opening

AboveAir VCU-C units use the same 36" x 19" opening as the Aerosys P Series, so they take the same custom replacement.

AboveAir modelTonsReplacementRefrigerant
VCU-C-018-1-S / VCU-C-018-1-X1.536"W x 19"H 1.5-Ton Thru-Wall CondenserR-454B
VCU-C-024-1-S / VCU-C-024-1-X2.036"W x 19"H 2.0-Ton Thru-Wall CondenserR-454B
VCU-C-030-1-S / VCU-C-030-1-X2.536"W x 19"H 2.5-Ton Thru-Wall CondenserR-454B

What this actually looks like in a New York City building

Finding the right part number is the easy half. The half that decides your schedule is everything around it. A through-the-wall changeover in a co-op means board approval, a certificate of insurance naming the building, a reserved service elevator, and a protected path from the loading dock to the apartment. In a prewar building it can also mean discovering that the sleeve was mortared into masonry in 1962 and nobody has touched it since.

Order the equipment before you have the approvals and you will be storing a two-hundred-pound condenser somewhere for a month. We sequence it the other way: confirm the opening and the sleeve condition, get the board package moving, then order against a real installation date. With a 14 to 21 day build on the 36 by 19 units, that sequencing is what keeps a summer failure from becoming a summer without cooling.

If you manage a whole line of these

Buildings rarely have one Aerosys unit. They have one per apartment on a line, all installed the same year, all now aging out together. Once the manufacturer is gone the question stops being whether to replace them and becomes when and in what order. The buildings that handle this well pick the failures off in planned batches during the shoulder season, when crews are available and residents are not sweating. The ones that wait end up paying emergency pricing in July, one apartment at a time, with a board meeting between each.

If your building already runs R-410A elsewhere, our R-410A equipment catalog covers what is still available in existing stock for the rest of the system. For the wider picture on planning a changeover, see our through-wall sizing guide, the co-op and condo approval guide, and our PTAC replacement guide if some of the building is still on PTACs.

Aerosys Replacement Questions

Tell us your model number and we will tell you what fits

Read the nameplate, measure the wall opening, and call. If it is one of the models above we can usually answer on the phone. If it is the 36 by 19, we build it, install it, and handle the building paperwork.

Or send us the details and we will get back to you.