1.5 Ton 1-Stg SS HP R-410A 14.3 SEER2 and 1.5 Ton Modular Multi Fan Coil and 4 kW Heat with Breaker
Goodman / TraneAir Handlers & Fan CoilsNew, no damage

1.5 Ton 1-Stg SS HP R-410A 14.3 SEER2 and 1.5 Ton Modular Multi Fan Coil and 4 kW Heat with Breaker

$2,379

As low as $199/mo with Affirm or Klarna

This Goodman / Trane unit is a 1.5 Ton indoor air handler, charged for R-410A. It is new stock, no damage, and it ships freight from our surplus channel, which is how the price lands where it does rather than at full distributor list. It runs on 208-240V power.

Air handler swaps are the most common retrofit we see in NYC commercial buildings. The unit has to fit through the door, up the stairs, or into the freight elevator, and the existing duct connections rarely line up on the first try. Measure the path in before you measure the unit. An ECM motor will usually pay for itself in a building running long hours.

On R-410A: new R-410A equipment stopped being manufactured on January 1, 2025, and the install-through window for remaining inventory closed at the end of 2025. What is left is existing stock. If you are maintaining a building that already runs R-410A, matching the refrigerant is far cheaper than converting the whole system, and this is where that equipment is coming from now. See our AHU retrofit guide for how this fits a larger building plan.

Manufacturer specifications: 1.5 Ton Single Stage Split-System Heat Pump, Circuit Voltage: 208-230, Hertz: 60, Phase: 1, Department of Energy Guide SEER2: 14.3, Stage: Single, Refrigerant: R410A, Connection Size: 3/8"X3/4", Connection Type: Sweat, Factory Charge: 94 oz, Type: Air, Dimensions: 35-11/16''H x 29''W x 29''D, Weight: 161 lbs ***Unit includes a Manufacture Warranty, register your unit with the Manufacturer for details*** Paired with: 1.5 Ton Modular Multi Position PSC Fan Coil,Voltage-208-230/60/1,Refrigerant-R-410A (Can Be Converted To R-22 With Optional TXV Coversion Kit), CFM:225-1091, Air Flow-Multi-Position, Metering Device-TXV, Connections-3/4 X 3/8, Connection Type-Sweat, SEER Unknown, Heat-No Heat, Type-Air Source, Dimensions- H-50" W-17.5" L-22", Weight-113Lbs, In Mfg. Box, Assembled In USA Paired with: 4 KW Electric Heat Kit With Breaker, Voltage:208-240, Hertz:60, Phase:1, Weight:10 Lbs, Dims:8"H 18"W 25"D, In Mfg Box, Origin: USA

Surplus stock moves. Confirm availability before you plan around it: (385) 319-1559

Specifications

SpecificationValue
ModelGSZB401810/GAM2A0A18S11SEA/BAYEAAC04BK1BA
Capacity1.5 Ton
RefrigerantR-410A
Voltage208-240
Hertz60
Phase1
CFM225-1091
Dimensions35-11/16''H x 29''W x 29''D
Weight161 lbs ***Unit includes a Manufacture Warranty
OriginUSA
Circuit Voltage208-230
StageSingle
Connection Size3/8"X3/4"
Connection TypeSweat
Factory Charge94 oz
TypeAir